Radiation Measurements

Papers
(The TQCC of Radiation Measurements is 4. The table below lists those papers that are above that threshold based on CrossRef citation counts [max. 250 papers]. The publications cover those that have been published in the past four years, i.e., from 2020-11-01 to 2024-11-01.)
ArticleCitations
The quest for new thermoluminescence and optically stimulated luminescence materials: Needs, strategies and pitfalls38
Calibration quartz: An update on dose calculations for luminescence dating30
A review and future of RPL dosimetry29
Exploring sources of variation in thermoluminescence emissions and anomalous fading in alkali feldspars24
Variation of luminescence sensitivity, characteristic dose and trap parameters of quartz from rocks and sediments24
Improvement on the performance of chemically cross-linked fricke methylthymol-blue radiochromic gel dosimeter by addition of dimethyl sulfoxide22
Spectral evidence for defect clustering: Relevance to radiation dosimetry materials19
Al2O3:C and Al2O3:C,Mg optically stimulated luminescence 2D dosimetry applied to magnetic resonance guided radiotherapy18
Optical characterization of LiF:Mg,Cu,P – Towards 3D optically stimulated luminescence dosimetry17
Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: Results of a field test16
Ag-doped phosphate glass with high weathering resistance for RPL dosimeter16
Lineal energy calibration of a mini-TEPC via the proton-edge technique16
Demonstration of an optically stimulated luminescence (OSL) material with reduced quenching for proton therapy dosimetry: MgB4O7:Ce,Li15
Machine learning as a tool for analysing the impact of environmental parameters on the radon exhalation rate from soil14
Improved performance of N-(Hydroxymethyl)acrylamide gel dosimeter using potassium chloride for radiotherapy14
Fetus dose calculation during proton therapy of pregnant phantoms using MCNPX and MCNP6.2 codes13
A review on reference dosimetry in radiation therapy with proton and light ion beams: status and impact of new developments13
The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy13
Microdosimetric modeling of the relative efficiency of Al2O3:C (Luxel, blue emission) optically stimulated luminescent detectors exposed to ions from 1H to 132Xe13
A non-destructive, high-sensitivity, emergency dosimetry method using OSL from protective back-glasses from smartphones12
Luminescence and dose-rate response properties of Pr-doped Bi4Ge3O12 scintillators12
A 2D imaging system for mapping luminescence-depth profiles for rock surface dating12
The effect of different lower detection thresholds in microdosimetric spectra and their mean values11
Characterization of 2D Al2O3:C,Mg radiophotoluminescence films in charged particle beams11
Comparison of airborne radiation detectors carried by rotary-wing unmanned aerial systems10
Timepix-based detectors in mixed-field charged-particle radiation dosimetry applications10
Timepix3: Temperature influence on X-ray measurements in counting mode with Si sensor10
Characterization of the neutron/γ-ray discrimination performance in 10
Principal Component Analysis applied to neutron dosimetry based on PADC detectors and FNTDs10
Development of real-time neutron detectors with different sensitivities to thermal, epithermal, and fast neutrons in BNCT10
History and future of radiation imaging with single quantum processing pixel detectors10
A LaBr3(Ce) detector system with a simple spectral shift correction method for applications in harsh environments9
EURADOS intercomparison on the usage of the ICRP/ICRU adult reference computational phantoms9
Time-resolved plastic scintillator dosimetry in MR linear accelerators without image distortion9
Personal neutron dosimetry: State-of-the-art and new technologies9
Annealing properties of the PVA-GTA-I gel dosimeter9
Consistency checks of results from a Monte Carlo code intercomparison for emitted electron spectra and energy deposition around a single gold nanoparticle irradiated by X-rays9
The ICRP recommended methods of red bone marrow dosimetry9
Detectors for measurement of microdosimetric quantities9
Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise8
Novel luminescence kinetic models for rock surface exposure dating8
Testing the effects of aspect and total insolation on luminescence depth profiles for rock surface exposure dating8
Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event8
On the production of the medium component in quartz OSL: Experiments and simulations8
A small-scale realistic inter-laboratory accident dosimetry comparison using the TL/OSL from mobile phone components8
Real-time dosimeter based on LiF:Mg,Cu,P and SiPM8
Evaluation of TL and OSL responses of CaF2:Tm for electron beam processing dosimetry8
Results of the EURADOS international comparison exercise on neutron spectra unfolding in Bonner spheres spectrometry8
Estimation of dose and elapsed time after unrecognized high-dose radiation exposure using the continuous-wave optically stimulated luminescence from Mg2SiO4:Tb8
Charge trapping processes in hydrothermally grown Er-doped ZnO7
BeOSL dosemeters and new ICRU operational quantities: Response of existing dosemeters and modification options7
Modeling the charge deposition in quartz grains during natural irradiation and its influence on the optically stimulated luminescence signal7
The GEMPix detector7
Study on the influence of sampling methods for measuring soil radon exhalation rates7
Performance testing of dosimeters used in interventional radiology: Results from the VERIDIC project7
A simplified multiple aliquot regenerative dose protocol to extend the dating limit of K-feldspar pIRIR signal7
Critical role of the deep electron trap in explaining the inconsistency of sensitivity-corrected natural and regenerative growth curves of quartz OSL at high irradiation doses7
Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise7
X-ray imaging at synchrotron research facilities7
Thermally assisted optically stimulated luminescence protocol of mobile phone substrate glasses for accident dosimetry7
A Monte-Carlo study on the fluorescent nuclear track detector (FNTD) response to fast neutrons: Which information can be obtained by single layer and 3D track reconstruction analyses?7
Photo and X-ray luminescence characteristics of CeF3 -doped SiO2 + B2O3 +AlF3 + NaF + CaF2 scintillating glasses7
Position of LiF:Mg,Cu,P TL peak as an alternative method for ultra-high-dose dosimetry7
Monte Carlo calculation of organ and effective dose rates from ground contaminated by Am-241: Results of an international intercomparison exercise7
Improved criterion of the mechanism for forming latent tracks in poly(allyl diglycol carbonate) based on the number of interactions induced by secondary electrons7
Dosimetric characteristics of lithium triborate (LiB3O5) nanophosphor for medical applications7
Irradiation of subcutaneous mouse tumors with a clinical linear accelerator validated by alanine dosimetry7
ESR thermochronometry of Al and Ti centres in quartz: A case study of the Fergusons Hill-1 borehole from the Otway Basin, Australia7
Thermoluminescent relative efficiency of TLD-100 glow peaks after exposure to X-rays of 20 kV–300 kV, 137Cs and 60Co gamma6
Performance of a new commercial high-definition 3D patient specific quality assurance system for CyberKnife robotic radiotherapy and radiosurgery6
A study on the use of modified extremity dosemeters for the measurement of H(3,α)6
Characterization of CaF2:Dy (TLD-200) dosimeters and determination of dosimetric quantities in mammography6
Investigating the potential of rock surface burial dating using IRPL and IRSL imaging6
Measurements of natural radiation with an MDU Liulin type device at ground and in the atmosphere at various conditions in the Arctic region6
Feasibility study of using earbuds and wireless headphones for retrospective dosimetry6
Intercomparison of micro- and nanodosimetry Monte Carlo simulations: An approach to assess the influence of different cross-sections for low-energy electrons on the dispersion of results6
On the various-heating-rates method for evaluating the activation energies of thermoluminescence peaks6
Evaluation of calibration methods of Exradin W2 plastic scintillation detector for CyberKnife small-field dosimetry6
Direct measurement of ionization chamber absorbed dose k factors in clinical electron beams6
EURADOS intercomparisons for individual monitoring services: Results of the 2016 and 2018 whole body dosemeters intercomparison for photon and beta radiations6
Investigation of the light output of 3D-printed plastic scintillators for dosimetry applications6
Investigation into the performance of dose rate measurement instruments used in non-governmental networks6
Development of a portable Single Sphere Neutron Spectrometer5
Dose response of visible color center radiophotoluminescence in lithium fluoride crystals irradiated with a reference 60Co gamma beam in the 1–20 Gy dose range5
A self-consistent FLUKA algorithm for studying the response of passive dosimeters based on CR-39 track detectors in fast neutron fields5
Recombination pathways in a BeO yielding two main dosimetric TL peaks5
Multispectral athermal fading rate measurements of K-feldspar5
Radiation and temperature effect of fiber Bragg grating sensor under Co-60 irradiation5
Using Infra-red stimulated luminescence and phototransferred thermoluminescence to investigate electron trapping and charge transport in feldspars5
Measurement of cosmic radiation in LEO by 1U CubeSat5
Optimized method for individual radon progeny measurement based on alpha spectrometry following the Wicke method5
MCNP 6.2 simulations of energy deposition in low-density volumes corresponding to unit-density volumes on the nanometre level5
Beam quality and dose rate dependency of Gafchromic EBT3 film irradiated with therapeutic megavolt photon beams5
ESR dating of quartz grains: Evaluating the performance of various cryogenic systems for dosimetric purpose5
Optimization of AlphaGUARD AquaKIT set-up for analysis of radon in water using stainless-steel bottles and its validation through IAEA standard samples5
Monte Carlo calculation of the organ equivalent dose and effective dose due to immersion in a 16N beta source in air using the ICRP reference phantoms5
Silver molecular clusters and the properties of radiophotoluminescence of alkali-phosphate glasses at high dose5
Photoluminescence, scintillation and thermoluminescent properties of Tb-doped BaCaBO3F5
A distributed and interconnected network of sensors for environmental radiological monitoring5
Fast scintillating Ce3+ doped gadolinium aluminum fluoroborate glass for calorimetry in proton CT prototype: A preliminary work5
The upper dating limit of the ESR signal at g=2.0006 in recrystallized carbonates5
On the dose dependence prior and after stimulation with visible light of E’ and Al-hole centres in sedimentary quartz: Correlation and mechanisms5
Translation of the absorbed dose in the mobile phone to organ doses of an ICRP voxel phantom using MCNPX simulation of an Ir-192 point source5
A role for oxygen vacancies in quartz luminescence5
Developing a radon monitor with less influence of humidity based on electrostatic collection method and CR-39 detector5
Advancing dosimetry for Dating Environmental Materials: Development of an ultra-sensitive beta dosimeter system and potential for beta autoradiography5
Effect of heating on the ESR signal of human fingernails4
Electron trap filling and emptying through simulations: Studying the shift of the maximum intensity position in Thermoluminescence and Linearly Modulated Optically Stimulated Luminescence curves4
The impact of accidental immersion in selected liquids on the sensitivity and repeatability of MCP-N thermoluminescent detectors4
Performance of a radiophotoluminescence (RPL) system in environmental and area monitoring4
Study on the uncertainty of passive area dosimetry systems for environmental radiation monitoring in the framework of the EMPIR “Preparedness” project4
Uncertainty evaluation for organ dose assessment with optically stimulated luminescence measurements on mobile phone resistors after a radiological incident4
High-rate X-ray spectroscopy in mammography with photon counting detectors using a limited number of energy bins4
A competitive radioluminescence material - LiF:Mg,Cu,P for real-time dosimetry4
Application of Machine Learning on sequential deconvolution and convolution techniques for analysis of images from Nuclear Track Detectors (NTDs)4
Radioluminescence-based fibre-optic dosimeters in radiotherapy: a review4
Modelling the dependence of equivalent dose determined from a dose recovery test on preheating temperature: The intervention of shallow electron traps4
Investigating optical dating of carbonate-rich cobbles from a river terrace: A pilot study from the Mula Valley, Spain4
Characterizing and comparing the kinetic parameters of Gd3+ doped hafnium oxide nanoparticles in clinical photon and neutron beam4
Study of a discriminative technique between radon and thoron in the Radout detector4
Relative efficiency of radiophotoluminescent glass detectors in low energy ion beams4
Development of a single sphere neutron spectrometer using α-Al2O3:C based optically stimulated luminescence detectors4
Examining features of radiation-induced damage to PADC observed using FT-IR analysis: Radiation tolerance of methine groups at three-way junctions4
The effect of particle size on the radiation dose response of luminescence signals from nanophosphors4
Performance of radiophotoluminescence personal dosimeters in terms of the ICRU Report 95’s operational quantities4
Infrared optically stimulated luminescence of rare earth doped CaF2 and co-doped with Al or Li produced by combustion synthesis4
Measurements of the doses of eye lens for the workers of Fukushima Daiichi Nuclear Power Plant4
Scintillation properties of composite films based on CsPbBr3 nanocrystals embedded in PMMA4
Image sorting of nuclear reactions recorded on CR-39 nuclear track detector using deep learning4
Thermoluminescence of aquamarine: A preliminary study4
The role of sodium ions in the thermoluminescence peaks of laboratory-irradiated natural quartz4
TSL and OSL properties of undoped and Eu-doped NaMgF3 translucent ceramics prepared by a spark plasma sintering method4
Persistent luminescence of commercial TLD-100 dosimeter: Using shallow traps for radiation dosimetry4
Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and4
Internal Bremsstrahlung emission during 32P decay4
Effect of temperature on performance of Boron Trifluoride (BF3) gas-based neutron proportional counters4
EPR Study of UV and gamma irradiated potassium persulfate: A Sensitive dosimeter4
Effect of radiation physics on inherent statistics of glow curves from small samples or low doses4
Development of BeO:Na,Yb,Dy ceramics for optically stimulated luminescence dosimetry4
The microdosimetric one-hit detector model for calculating the relative efficiency of the alanine pellet dosimeter in low energy X-ray beams4
Characterisation of a customised 4-chip Timepix3 module for charged-particle tracking4
Analysis of the uncertainties in the dose audit system using radiophotoluminescent glass dosimeters in Japanese radiotherapy units4
Response of the Ti and Al electron spin resonance signals in quartz to X-ray irradiation4
Signal-stabilized Al2O3:C-OSL dosimeter “checking chip” for correcting OSL reader sensitivity variation4
OSL with chips from US credit cards4
Infrared-radiofluorescence: Dose saturation and long-term signal stability of a K-feldspar sample4
0.54380798339844